RM Analyzer Help

Template > Combination Table DIN FB

Loading a template combination table according to DIN-FB.

The default names of the load cases and superposition files can be changed directly or by selecting  them from the list.

Options: The predefined combination tables either can directly be import into data base or alternatively a TCL file for later import can be generated. It is possible to "Save" all modification in this input pad at any label name. And "Load" will  restore this input in a later call of this template.

Abstract of predefined Load-Combinations

Combination I and II - "permanent loads"

  • Comb.I: Pk, t=0
  • Comb.II: Pk, t=oo

SLS - Combinations III to V - "rare combination"

  • Comb.III: Pk, t=0
  • Comb.IV: Pk, t=oo
  • Comb.V: Pm, t=0, t=oo

SLS - Combination VI - "infrequent combination"

  • Comb.VI: Pm, t=0, t=oo

SLS - Combination VII - "frequent combination"

  • Comb.VII: Pm, t=0, t=oo

SLS - Combinations VIII to X - "quasi-permanent combination"

  • Comb.VIII: Pk, t=0
  • Comb.IX: Pk, t=oo
  • Comb.X: Pm, t=0, t=oo

ULS - Combinations XI and XII - "characteristic" and "transient design situation"

  • Comb.XI: gr1
  • Comb.XII: gr2

Combinations XIII and XIV - special combinations

  • Comb.XIII: bearing capacity
  • Comb.XIV: fatigue